Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.13652614
![](http://i.b2b168.com/e/tag_pthy.gif)
- Product Categories
- Friendly Links
Information Name: | Fluke DTX-1800 |
Published: | 2015-05-21 |
Validity: | 365 |
Specifications: | |
Quantity: | 23.00 |
Price Description: | |
Detailed Product Description: | Overview of outstanding Class IV precision, beyond the standard Cat 5e / 6/7 is required to complete a Cat 6 automated test takes only 12 seconds, at least three times faster troubleshooting capabilities of advanced time-saving than the previous tester, can accurately indicate the fault, but also provide repair recommendations 900MHz frequency range, for your future applications ready. Such as Gigabit Ethernet, Class F links or CATV. Beicha fiber module, a single bond can be between copper and fiber test switch DTX significantly reduces the overall cost of certification testing, up to 335 characteristics can save money each year, DTX Upgrade Option DTX series cable certification analysis instrument to protect your investment, but also to meet the future needs, from any kind of module you can simply and easily upgrade to higher performance modules, including the DTX-1800. DTX-1200 upgrade to DTX-1800 If you purchased DTX-1200, using the DTX-1218U upgrade package can be upgraded to DTX-1800. Host and Smart Remote at the same time be upgraded, after upgrading the test frequency up to 900MHz, with optional Class F Permanent Link and channel adapters have a Class F test capability; these adapters are not included in the upgrade kit. Kit contains a 16MB MMC card and a serial computer interface cable (IEEE 1394 connector to DB9). Upgrade Kit contains a list of upgrade instructions, above the contact Fluke Networks to upgrade your tester of information at an authorized repair station. Technical staff will be on your host and remote upgrades, and returned to you. Second, the high-speed fiber certification test button switch twisted pair and fiber optic test only optional DTX fiber modules provide a platform that lets you will never waste time looking for the cable adapter. For cable certification testing possible at any time. DTX Series tester gu through a unique technology and easy to use interface reduces test time. Press Auto Test button will automatically meet the criteria of certification - two cable, the two wavelengths simultaneously test. Also measure length, and determine the test is passed or not - all tests are completed in 12 seconds. Our fiber test module can do more tests in a shorter period of time, reduce testing costs, while giving you more time to do other work. Reduce test time per year can easily more than 100 hours. We provide a complete level of certification of a comprehensive certification test includes loss, length and polarity test. You can confirm the performance and quality of the installation of fiber optic cable link. Cable loss measurements at multiple wavelengths, measure the length of the cable and verify its polarity. You can bi-directional testing without having to swap places with the remote host on the two cable link, only from Fluke Networks test instrument only has this capability. Unlike other fiber optic test adapters at each automated test only length and two loss measurements, DTX Series testers cable adapter is the only test in an automatic test program can be completed in length and four loss measurements - only 12 seconds. In the cable test, you can have five times faster than the speed of other programs. Third, the copper and fiber certification test suite if you are both twisted pair copper cabling certification testing, but also on the cable certification testing, we can provide you with Kit. The package offers the DTX Series CableAnalyzer and fiber modules bundled together, so you can simultaneously copper and fiber certification testing. If the above package offers not fully meet your needs, you can choose to purchase separately DTX Series CableAnalyzer and DTX Series fiber test modules. Fourth, the use LinkWare Cable Test Management software saves the management of test results time DTX Series CableAnalyzer contains Fluke powerful networking features LinkWare cable management software, which can help you to quickly test results through the work place, user, Construction etc. organize, edit, view, print, save or archive. You can merge test results into an existing database, sorted by any data fields or parameters to find or organization. You can download for free from our website LinkWare software, once you have completed the work, you can be this powerful application submitted to your users, so they can immediately access the electronic data, you can also just be data Export to Adobe PDF documents. LinkWare software extensive data management capabilities: using a single software manages copper and fiber test results to support the Fluke Networks line of cable testers for all Fluke Networks cable testers to common format get professional graphics test reports to ensure compliance with the configuration and print TIA Standard 606-A documentation New drag and drop feature makes it easier to manage and organize multiple projects and powerful CMS cable management software compatible features a simple user interface and time-saving improve productivity, which is the world's preferred cable Test Management Software LinkWare software color graphics describes the measured parameters, you can print professional, graphical test reports. You can choose which order parameters and graphic display of the print. You can customize reports on the company LOGO. New LinkWare Stats option provides statistical reports for all your cable graphical analysis device now supports LinkWare Stats LinkWare report statistical software, which is a new automated statistical report option that can help you move above and beyond the page-per -link report, review your entire cable structure. It LinkWare cable test data analyzed and converted to a graphic in a compact, graphical format to show the cumulative performance of your entire cable structure cable equipment, so you can easily verify the border, found no abnormalities. LinkWare Stats to see how to handle your data --LinkWare cable management software included in the free DEMO version of LinkWare Stats. Fifth, the most efficient certification test program for 12 seconds 6 Autotest faster than other testers three times more than 6 class IV level precision and higher standards of the indicator advanced troubleshooting techniques to quickly pinpoint any location link The fault and the fault of the right way to help you troubleshoot. For field environments Permanent Link Adapter provides high test accuracy and repeatability powered ready DTX fiber modules series with 6 class system compatibility 12 hours battery life lithium-ion battery is a long day of work Beicha optical cable module slots for optional fiber module provides protection for 12 seconds while the automatic test cable dual cable dual wavelength certification test internal memory can save more than 250 graphic formats, or 2000 provision Category 6 link test reports format 300 Category 6 link test reports test bandwidth storage cards for fast data processing --16MB memory card can save graphics formats up to 900MHz to support video transmission, Class F or Gigabit Ethernet applications with a large color screen displays high brightness background light, easy to observe the test result data port high speed USB download of test data storage full graphical test results can be downloaded through Fluke Networks' LinkWare software to the PC lightweight and portable, ergonomic design is built for field use for talk feature allows you and your partner can communicate via twisted pair or fiber optic cable at both ends of the link. rotary switches easy to learn and easy to operate that you always know the selected test mode robust jacket to meet a variety of field environments Six requirements, significantly reducing the time of certification testing DTX Series Digital Cable Analyzer provides you a complete set of test programs to make every aspect of certification testing are simple and orderly - ranging from setting to quickly test and fault diagnosis, to generate test reports for each stage. In short, DTX series can save a lot of time and money for you - savings of up to four hours a day. Completed Category 6 link test DTX-1200 and DTX-1800 in 12 seconds and can be completed within 12 seconds of 6 class test link - not fully meet the current international standards, but also has ultra-high precision, this three times faster than the existing speed tester. This incredible speed means you work eight hours a day can be more time to test more than 170 links. Troubleshooting twice as fast When a link is faulty, DTX Series testers can provide a quick and straightforward way to represent the exact location of the fault (the fault distance from the tester) and the possible causes of failure. The message not only tells you of what went wrong, but also provides you the right way to solve the problem quickly - so there is no need to spend time to consult staff in charge of the project. Do not waste time to experiment, to explore troubleshooting methods, and re-tested to determine if the fault has been resolved - testers can clearly know where the failed link what problems emerged, what do you need to troubleshoot . In addition to saving time testing session DTX Series testers just speed test faster, it also reduces the time to set up and generate reports. Its easy to use features reduce training time; time means longer battery life on a single charge, you can do more testing; bright color display, ample memory, and built-in walkie-talkie with the use of personnel continue to accumulate The actual test experience, which all helps to improve the overall efficiency of the test. In daily test work, DTX series unknowingly save you time, save money. Seven permanent link test adapter jumper commercial technology to reduce false positives - including 5e, Cat 6 or even 7 class - if directly used to test the permanent link, it will result in many false positives qualified link, waste a lot of time to diagnose the problem and repeat the test. The reason due to repeated curling jumpers and expansion, as well as the live environment careless storage and other daily wear and tear, can cause it to continue to decrease over time, the most obvious is the impact of the return loss, which are usually caused by the test failed . At Fluke Networks, we guarantee the accuracy of the test in the first place. That's why we develop high-performance permanent link test adapter jumper to replace commercial reasons. Our proprietary technology ensures a higher return loss measurement accuracy and stability, but also improves the accuracy of all other test parameters - not just a first test of accuracy, but each test precision - long-term precision. As you can see from the figure, a commercial Class 7 SSTP jumpers have 10dB of loss at 150 after curling and expand. This will result in the loss of 10dB qualified link is mistaken for failure - you get a false fail results. If you are using a Fluke Networks Permanent Link adapter is not such a case --DTX series testers will bring you no doubt repeat test accuracy happen. Eight, cabling manufacturers recognized when you decide to means test, recognized manufacturers is necessary. With the manufacturer's warranty, you should use the recognized testing tool can also perform certification testing, so we can ensure your customer satisfaction. Fluke Networks DTX Series CableAnalyzer through some of the industry's leading routing vendors rigorously tested in a laboratory. Click below to display the manufacturer's authorized channel LOGO. Nine, for the future needs of 900MHz test frequency DTX Series CableAnalyzer top model --DTX-1800-- supports up to test the frequency of 900MHz. This high bandwidth to support the requirements of ISO Class F links, and meet 10 Gigabit Ethernet twisted-pair test run. It also helps you to authenticate the other link applications such as video transmission over twisted-pair cabling systems. On the market there is no other test in compatible 5e, Category 6 testing requirements while protecting your investment in order to adapt to future needs. Ten, beyond the level of the IV tester accuracy far, the tester is designed to meet the accuracy requirements of class III. ISO / IEC (International Standard) requires Class F links to be tested to 600MHz, and the need to meet the requirements of the tester IV level precision. DTX Series meet and exceed this requirement to ensure that your test results over the entire frequency range have higher credibility. The cost of inaccurate test: tester shows incorrect pass / fail judgment result in the qualifying link deemed to have failed, or will fail the link judged to be acceptable. Both can waste a lot of your time and money. XI, 2 times faster fault diagnosis When a link is faulty, DTX Series testers can provide quick and straightforward way to represent the exact location of the fault (the fault distance from the tester) and the possible failure the reason. The message not only tells you of what went wrong, but also provides you the right way to solve the problem quickly - so there is no need to spend time to consult staff in charge of the project. Do not waste time to experiment, to explore troubleshooting methods, and re-tested to determine if the fault has been resolved - testers can clearly know where the failed link what problems emerged, what do you need to troubleshoot . Even if only two percent of the problem being tested link in a day's work, you can save two hours of time. Menu DTX Series testers feature cable analyzer DTX-1800 DTX-1200 DTX-LT to complete a full Category 6 link automatic test of time (in seconds) 9930 highest measurement bandwidth (MHz) 900 350 350 tester accuracy level IV IV IV Chinese color graphics display memory test report SSS SSS internal memory capacity (graphical Cat 6 test reports link) 250 250 250 Pluggable memory card, 16MB capacity 300 300 N / A lithium-ion battery - a charge time ( h) 12 12 12 Intelligent Fault Diagnosis SSS SSS USB Interface Serial Interface SSN / A 6 class permanent link adapter SSS 6 class channel adapters SS optional support for fiber module slots concealed from the smart remote start SSS SSS host of automatic test Upgrade and intercom between SSS distal to DTX-1800 N / A Optional Optional Standard accessories fiber module (multimode and single mode) Optional Optional 7 class permanent link adapter optional N / AN / A 7 class channel adapters Optional N / AN / A multimedia memory card S Optional N / A USB cable SSS serial cable S Optional Optional Optional carrying walkie-talkie headset SS SSS NOTE: S- standard configuration, N / A- do not have This feature; annex does not apply; optional - sold separately attachments technical indicators: |
Admin>>>
You are the 6870 visitor
Copyright © GuangDong ICP No. 10089450, Beijing Ming Chen Chi Hang Technology Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 6870 visitor
Copyright © GuangDong ICP No. 10089450, Beijing Ming Chen Chi Hang Technology Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility